ANTARIX Tomographic System IMX-4A
ANTARIX Tomographic System IMX-4A is a radiological table with potter bucky and vibrating grid, manual light beam collimator, column and tomographic group.
The table top is flat and particularly suitable for injured and disable patients thanks to its elevating feature by means of push buttons and the possibility to horizontally move the table top in all directions by means of foot pedal.
The column, sliding on floor rails, with the facility of x-ray tube arm rotation, allows you to operate in combination with Vertical Bucky for upstanding radiographies.
Device in conformity to 93/42/CEE directive.
See the scheme » Dimensions of ANTARIX Tomographic System IMX-4A »
Specifications ANTARIX Tomographic System IMX-4A
DESCRIPTION | DATA |
Power supply | 230Vac +/- 10% 50Hz 5A |
Weight of the equipment | 562 kg |
TABLE | |
Table top dimensions | 2200 x 747 mm |
Height from the ground | 810max – 736(tomo) – 550min mm |
Longitudinal run | ± 407 mm |
Transversal run | ± 120 mm |
Table top to film distance | 98 mm |
Potter bucky longitudinal run | 515 mm |
Max patient’s weight | 250 Kg |
Suitable cassette sizes | See bucky |
Absorption coefficient | ≤ 0,8 mm Al. |
Potter Bucky | 24V 50Hz 1A 230V 50Hz 1A |
Grid | 480mm x 436mm 103 LPI – R10.1 Foc. 100 cm |
TOMOGRAPHIC FUNCTION | |
Layer height | From 0 to 240 mm |
Focus film distance | 1000 mm |
TUBE STAND | |
Tube arm vertical movement | Min. 520 mm Max. 1950 mm |
Tube arm transversal movement | 15 cm ( OPTIONAL ) |
Tube arm rotation around horizontal axis | ± 110° |
Stand maximum rotation on its vertical axis with mechanical bloc every 90° | ± 180° |
Focus film distance | Min. 1000 mm – Max. 1200 mm |
COLLIMATOR PREDISPOSITION | |
Max. Weight | 9,7 Kg |
Check compatibility with X-ray tube | |
Lamp’s power supply | 24V~ with 3 poles cable (2+ grounding) |
Models | Please contact us for compatibility check |
TUBE PREDISPOSITION | |
Max. Weight | 24 Kg |
Check compatibility with collimator | |
Models | Please contact us for compatibility check |
ELECTRIC CLASSIFICATION | |
Class | CEI EN 60601-1 (Class I type B) and further corrections |
REQUIRED ENVIRONMENTAL FEATURES | |
Temperature (operative) | +10°C to +35°C |
Temperature (storage) | –10°C to +40°C |
Maximum Humidity | 80% without dew |
Maximum Altitude for using | 3500 meters |
TOMOGRAPHIC TIMES | |||||
ANGLE | |||||
SPEED | 8° | 15° | 30° | 45° | |
I | 0.16 | 0.28 | 0.59 | 0.95 | |
II | 0.23 | 0.38 | 0.81 | 1.27 | |
III | 0.27 | 0.45 | 0.98 | 1.54 |